Grow Room Humidifier Sizing Calculator

Find the L/hr or pints per day output you need from room size, temperature, and humidity targets.

Measure at canopy level.
Propagation 65 to 80, veg 55 to 70, flower 40 to 55.
Recommended humidifier output 0.00 L/hr 0 pints/day
Room volume
0 ft³
Moisture deficit
0.00 g/m³
Minimum required
0.00 L/hr
Minimum in pints/day
0 PPD

Pick a unit rated at or above the recommended output. 1 L/hr is about 50.7 pints per day.

Talk to us
How this is calculated

Absolute humidity (g/m³) is computed at your air temperature for the current and target RH using the Magnus saturation vapor pressure equation. The difference is the moisture deficit. Required output (L/hr) = deficit × room volume (m³) × air changes per hour ÷ 1,000, multiplied by the light type factor. The recommended figure adds the sizing buffer. Simple mode uses 3 ACH and a 25% buffer.