Water Chiller Sizing Calculator

Find the BTU/hr and HP rating your reservoir needs from volume and temperature, with optional light and room heat.

Include all water in the system: reservoir, buckets, and plumbing.
Measure at its warmest, during lights on with no chiller.
65 to 68 °F suits most hydro crops.
Minimum chiller size0 BTU/hr with 20% buffer
Temperature differential
0.0 °F
Base load (water pull-down)
0 BTU/hr
Total before buffer
0 BTU/hr (0.00 tons)
Size up one tier

A larger chiller runs fewer hours and lasts longer. Sizing up one tier is the usual advice.

Talk to us
Chiller sizes and formula
ChillerCapacityReservoir range (DWC)Reservoir range (NFT / drip)
1/10 HPabout 800 BTU/hrup to 26 galup to 35 gal
1/4 HPabout 2,500 BTU/hr26 to 65 gal35 to 90 gal
1/2 HPabout 5,500 BTU/hr65 to 145 gal90 to 190 gal
1 HPabout 10,000 BTU/hr145 to 265 gal190 to 350 gal
1.5 HPabout 15,000 BTU/hr265 to 400 gal350 to 525 gal
2 HPabout 20,000 BTU/hr400+ gal525+ gal

BTU/hr = gallons × 8.34 × temperature differential × system factor. Advanced adds 10% of light wattage as heat reaching the water (watts × 3.412 × 0.10) and 2% per °F that ambient exceeds 75 °F. Then a 20% safety buffer. Tons = BTU/hr ÷ 12,000.