Ventilation & Carbon Filter Sizing Calculator
Size your inline fan and carbon filter from room volume, air exchange target, and duct losses.
Loss factors. Each one reduces effective airflow.
- Room volume
- 0 ft³
- Base CFM
- 0 CFM
- After climate factor
- 0 CFM
- Total loss
- 0%
- CFM needed to overcome losses
- 0 CFM
- With headroom
- 0 CFM
| Loss factor | Loss |
|---|
Match your carbon filter to the fan's rated CFM, not the base requirement. Mount the filter on the exhaust side.
How this is calculated
Base CFM = room volume ÷ exchange time in minutes. Required CFM = base × climate factor ÷ (1 − total loss fraction) × (1 + headroom). Simple mode assumes a standard carbon filter (20%), 10 ft of flexible duct, and one 90° bend. Fan size suggestions use common inline fan ratings: 4 inch up to about 190 CFM, 6 inch up to about 440 CFM, 8 inch up to about 750 CFM, 10 inch up to about 1,000 CFM.